Download Instek Gpi-745a Manual

• A Solid Foundation for Reliable, Safe and Practical Safety Compliance Testing GW Instek is launching to the market a new series of safety tester with high durability and multiple user-protection design. The GPT-9800 Series look to meet a variety of safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety-related requirements for the safety tests of electronic products and components. A total of 4 safety testers in the GPT-9800 Series, namely GPT-9804, GPT-9803, GPT-9802 and GPT-9801, are available for various applications. The GPT-9804 is a 4-in-1 model capable of performing AC withstanding, DC withstanding, insulation resistance and ground bond tests. The GPT-9803 is a 3-in-1 model capable of performing AC withstanding, DC withstanding as well as insulation resistance tests. The GPT-9802 is capable of performing both AC and DC withstanding tests, whereas the GPT-9801 is able to perform AC withstanding test. The series of safety tester is built upon a high-efficiency PWM amplifier platform with AC 200VA maximum output capacity to impede the influence from the voltage fluctuation of the input AC source.

Download Instek Gpi-745a Manual

This ensures a stable voltage supply for all the tests of the GPT-9800 Series. PWM Amplifier Efficiency Unlike the conventional safety tester design that uses variable voltage transformer and class AB amplifier to provide testing voltage, the GPT-9800 Series, carrying a high-efficiency PWM amplifier design, generates output source up to 98% efficiency. This greatly reduces the amount of power loss to heat and therefore lowers the temperature within the cabinet of the GPT-9800 Series. The suppression of temperature rise during heavy-duty operations of the tester significantly increases its reliability and service lifetime. In addition, as PWM amplifier is comparatively more resistant to the fluctuations of input power voltage, a stable high-voltage output with less than 1% regulation is provided by the GPT-9800 Series to perform precision tests of the DUT.

In order to provide high accuracy testing for production test, regulation compliance, and characteristic verification, the withstanding test voltage (AC 5kV/DC 6kV) of the GPT-9800 Series can be adjusted in 2V steps, while the current measurement can be done with 1μA resolution and ±(1.5% + 30μA) accuracy to enable small leakage current measurements of the products or the components. In addition, the test voltage of insulation resistance of the GPT-9800 Series can be adjusted in 50V steps within the DC output range from 50V to 1000V, carrying a measurement accuracy of ±(10% of reading +1 MΩ) at full scale (2000MΩ/9500MΩ). This provides the flexibility for performing I.R.

Measurements under variable levels of applied voltage. As the majority of safety regulations need an AC source for ground bond testing, the GPT-9800 Series provides 6Vac voltage (open circuit) and 3A~30Aac current for ground bond test, meeting IEC 60601-1 requirements. Furthermore, open circuit detection (via SOURCE H, SENSE H and SOURCE L terminals) for ground bond testing is also provided to check whether the test apparatus is properly connected before the start of a test. Photoshine V3.5 Full With Keygen - And Reviews 2017.

Safety Testers - Safety Testers (Hi- Pot Tester) - Electrical Safety Tester, GPT- 9. A Solid Foundation for Reliable, Safe and Practical Safety Compliance Testing.

This is to ensure the ground bond test is done accurately without any unnoticeable misconnection of the test leads and the test terminals. With these capabilities, the user is able to perform various safety tests and verifications with high flexibility, accuracy and confidence.

Output Voltage Variation in One Test Cycle Zero-Crossing Operation Once the GPT-9800 Series is turned on, the protection functions to protect operator and DUT are always in operation throughout the testing period. When the power is turned on, the GPT-9800 Series immediately goes through the self-check procedures to ensure that all test functions are performed under normal conditions, as the first protection function being applied.The second protection function is activated once the “Start” (output) button is pressed. At the first moment of start up, the GPT-9800 will send a detection voltage (~100V) during the initialization period (100ms) to check whether the DUT has any short circuit due to poor insulation before the high voltage is applied. This is to prevent high voltage or current from returning to the DUT during the test time. To protect DUT from insulation breakdown caused by the rapid increase of test voltage at power-on and avoid flashover or arcing phenomena that could affect the test results, the GPT-9800 Series has a Zero Crossing Turn-On feature, which ensures the output always starts from the zero crossing of a sine wave.